Freescale Semiconductor /MKE14D7 /IEVENT /BFECR0

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as BFECR0

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (00)PT3_DC 0 (00)PT3_CC 0 (00)PT3_BC 0 (00)PT3_AC 0 (00)PT2_DC 0 (00)PT2_CC 0 (00)PT2_BC 0 (00)PT2_AC 0 (00)PT1_DC 0 (00)PT1_CC 0 (00)PT1_BC 0 (00)PT1_AC 0 (00)PT0_DC 0 (00)PT0_CC 0 (00)PT0_BC 0 (00)PT0_AC

PT1_CC=00, PT0_BC=00, PT2_BC=00, PT3_CC=00, PT3_BC=00, PT1_AC=00, PT3_DC=00, PT3_AC=00, PT0_DC=00, PT1_DC=00, PT0_CC=00, PT1_BC=00, PT2_CC=00, PT0_AC=00, PT2_DC=00, PT2_AC=00

Description

iEvent Boolean Function Eva1ation Configuration Register

Fields

PT3_DC

Product Term 3, D input Configuration

0 (00): Force the D input in this product term to a logical zero.

1 (01): Pass the D input in this product term.

2 (10): Complement the D input in this product term.

3 (11): Force the D input in this product term to a logical one.

PT3_CC

Product Term 3, C input Configuration

0 (00): Force the C input in this product term to a logical zero.

1 (01): Pass the C input in this product term.

2 (10): Complement the C input in this product term.

3 (11): Force the C input in this product term to a logical one.

PT3_BC

Product Term 3, B input Configuration

0 (00): Force the B input in this product term to a logical zero.

1 (01): Pass the B input in this product term.

2 (10): Complement the B input in this product term.

3 (11): Force the B input in this product term to a logical one.

PT3_AC

Product Term 3, A input Configuration

0 (00): Force the A input in this product term to a logical zero.

1 (01): Pass the A input in this product term.

2 (10): Complement the A input in this product term.

3 (11): Force the A input in this product term to a logical one.

PT2_DC

Product Term 2, D input Configuration

0 (00): Force the D input in this product term to a logical zero.

1 (01): Pass the D input in this product term.

2 (10): Complement the D input in this product term.

3 (11): Force the D input in this product term to a logical one.

PT2_CC

Product Term 2, C input Configuration

0 (00): Force the C input in this product term to a logical zero.

1 (01): Pass the C input in this product term.

2 (10): Complement the C input in this product term.

3 (11): Force the C input in this product term to a logical one.

PT2_BC

Product Term 2, B input Configuration

0 (00): Force the B input in this product term to a logical zero.

1 (01): Pass the B input in this product term.

2 (10): Complement the B input in this product term.

3 (11): Force the B input in this product term to a logical one.

PT2_AC

Product Term 2, A input Configuration

0 (00): Force the A input in this product term to a logical zero.

1 (01): Pass the A input in this product term.

2 (10): Complement the A input in this product term.

3 (11): Force the A input in this product term to a logical one.

PT1_DC

Product Term 1, D input Configuration

0 (00): Force the D input in this product term to a logical zero.

1 (01): Pass the D input in this product term.

2 (10): Complement the D input in this product term.

3 (11): Force the D input in this product term to a logical one.

PT1_CC

Product Term 1, C input Configuration

0 (00): Force the C input in this product term to a logical zero.

1 (01): Pass the C input in this product term.

2 (10): Complement the C input in this product term.

3 (11): Force the C input in this product term to a logical one.

PT1_BC

Product Term 1, B input Configuration

0 (00): Force the B input in this product term to a logical zero.

1 (01): Pass the B input in this product term.

2 (10): Complement the B input in this product term.

3 (11): Force the B input in this product term to a logical one.

PT1_AC

Product Term 1, A input Configuration

0 (00): Force the A input in this product term to a logical zero.

1 (01): Pass the A input in this product term.

2 (10): Complement the A input in this product term.

3 (11): Force the A input in this product term to a logical one.

PT0_DC

Product Term 0, D input Configuration

0 (00): Force the D input in this product term to a logical zero.

1 (01): Pass the D input in this product term.

2 (10): Complement the D input in this product term.

3 (11): Force the D input in this product term to a logical one.

PT0_CC

Product Term 0, C input Configuration

0 (00): Force the C input in this product term to a logical zero.

1 (01): Pass the C input in this product term.

2 (10): Complement the C input in this product term.

3 (11): Force the C input in this product term to a logical one.

PT0_BC

Product Term 0, B input Configuration

0 (00): Force the B input in this product term to a logical zero.

1 (01): Pass the B input in this product term.

2 (10): Complement the B input in this product term.

3 (11): Force the B input in this product term to a logical one.

PT0_AC

Product Term 0, A input Configuration

0 (00): Force the A input in this product term to a logical zero.

1 (01): Pass the A input in this product term.

2 (10): Complement the A input in this product term.

3 (11): Force the A input in this product term to a logical one.

Links

()